无标题文档
|
|
|
 |
|
 |
|
|
Total 6 Records Current 5 Page/Total 6 Page ==《CATALOGUE ONLINE》==  3 4 5 6  | |
60w triple output |

159×97×38mm |
Summary:
Single unit output:powers 60W Input voltageAC AC 85~264V . Selected by swich Output voltage:The voltage we all can produce between3V-48VDC
| |
|
|
Model
Specification |
T-60A |
T-60B |
T-60C |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
Specification |
5V? 5A |
12V2.5A |
-5V0.5A |
5V5A |
12V2.5A |
-12V0.5A |
5V5A |
15V2A |
-15V0.5A |
Wave and noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Inlet stability |
±0.5% |
±1% |
±0.5% |
±0.5% |
±1% |
±0.5% |
±0.5% |
±1% |
±0.5% |
Load stability |
±1% |
±4% |
±1% |
±1% |
±4% |
±4% |
±1% |
±4% |
±1% |
Efficiency |
72% |
72% |
72% |
Adjustable range for DC voltage |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
AC input voltage range |
85~264VAC? 47~63Hz; 120~370VDC |
AC input voltage range |
Cold-start current 30 A/115V 60A/230V |
OverLoad protection |
105%~150% hiccup mode,auto-recovery |
OverLoad protection |
CH1:5.75~6.75V |
Setup,rise,hold up time |
800ms, 50ms, 10ms/115VAC? 300ms, 50ms,80ms/230VAC |
Withstand voltage |
I/P-O/P:3KvAC I/P-FG:1.5KvAC O/P-FG:0.5KvAC 1minute |
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ |
Working temperature |
-10℃~+50℃ |
Safety standards |
Design refer to GB4943,UL60950,EN60950 |
EMC standards |
Design refer to GB9254,EN55022 class A |
Weight |
0.56Kgs | |
|
Terminal Pin No.Assignment |
Pin 1.2 : AC input |
Pin 3 : GND  |
Pin 4 : DC output-V |
Pin 5 : DC output+ V2 |
Pin 5 : DC outputC0M |
Pin 5 : DC output+ V1 |
| |
|
|
|
|
|
 |
|
 |
Total 6 Records Current 5 Page/Total 6 Page ==《CATALOGUE ONLINE》==  3 4 5 6  |
| |
|
|
|
|
|
|