Total 6 Records Current 4 Page/Total 6 Page ==《CATALOGUE ONLINE》==  3 4 5 6  | |
50w triple output |

159×97×38mm |
Summary:
Single unit output:powers 50W Input voltageAC 110/220VAC±20% . Selected by swich Output voltage:The voltage we all can produce between3V-48VDC
| |
|
|
Model
Specification |
T-50A |
T-50B |
T-50C |
T-50D |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
Specification |
5V7A |
12V1A |
-5V1A |
5V5A |
12V1A |
-12V1A |
5V4A |
15V1A |
-15V1A |
5V3A |
12V1A |
24V1A |
Wave and noise |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
100m Vp-p |
120m Vp-p |
120m Vp-p |
50m Vp-p |
120m Vp-p |
120m Vp-p |
Inlet stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1% |
±1% |
Load stability |
±0.5% |
±4% |
±4% |
±1% |
±4% |
±4% |
±1% |
±4% |
±4% |
±1% |
±5% |
±5% |
Efficiency |
66% |
69% |
71% |
72% |
Adjustable range for DC voltage |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
CH1:+10,-5% |
AC input voltage range |
85~132VAC/170~264VAC Selected by switch 47~63Hz,240~370VDC |
AC input voltage range |
Cold-start current 20 A/115V 40A/230V |
OverLoad protection |
105%~150% hiccup mode,auto-recovery |
OverLoad protection |
………………… |
Setup,rise,hold up time |
200ms.50ms.16ms |
Withstand voltage |
I/P-O/P:1.5KvAC I/P-FG:1.5KvAC O/P-FG:0.5KvAC 1minute
|
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC/100MΩ |
Working temperature |
-10℃~+50℃ |
Safety standards |
Design refer to GB4943,UL60950,EN60950 |
EMC standards |
Design refer to GB9254,EN55022 classA |
Weight |
0.54Kgs | |
|
Terminal Pin No.Assignment |
Pin 1.2 : AC input |
Pin 3 : GND  |
Pin 4 : DC output-V |
Pin 5 : DC output+ V2 |
Pin 6 : DC outputcom |
Pin 7 : DC output+ V1 |
| |
|
|
|
|
|
 |
|
 |